This safety standard is intended to be employed in ordinary locations by NFPA 70.

General requirements for protection against the risk of injury

All automatic residential garage door operators that have an electronic circuit acts as a backup, preventing the risk of fire, electric shock, or injury to persons, must meet the requirements in UL 991, including environmental and stress tests appropriate to the intended usage of the end- product.

General testing parameters

Contingent on electrical oversight of cynical parts, a door closing motion operator is inoperative and meets the standard for trouble indication.

In the evaluation of entrapment protection circuits installed in residential garage door operators, the critical condition flow chart to subpart A shall be used. During the power cycling safety for tests by UL 991.

General entrapment protection requirements

Inherent main trap protection should be given to a residential garage door operator scheme that meets the demands. One of the following parameters should also be followed by a vertically moving housing garage door operator:

  • Should be built to;

  1. To lower the gate, continuous pressure is needed on the control to be mounted and enabled along the door line of sight.
  2. Once continuous pressure on control is removed before the operator reaches its reduced limit, reverse direction, and open the gate to the highest position.

iii.            When provided, a mobile transmitter should be restricted only to make the operator open the gate.

  • A means of connecting an internal secondary trap protection device should be given.
  • A secondary trap protection device should be given.

 

Inherent primary entrapment protection requirements

  • General specifications – a vertically moving residential garage door operator system should be provided with intrinsic main trapping protection by the criteria set out in (b). A horizontal sliding garage door operator system should be provided with intrinsic main trap protection that meets the requirement set out in (c).
  1. Inherent protection of the main trapping for vertically moving gates
  2. For a vertically moving residential garage door operator system, other than for the first1-foot door travel from the full highest position with or without any functional secondary external interlocking device, the operator of the down moving residential garage door should initiate a reversal of the door within 2 seconds of reaching the interlock. The operator should return the gate to and stop at the complete top position after reversing the gate.
  3. The entryway administrator ought to not return the entryway to, and halt the entryway at, the complete highest position when the administrator faculties any moment hindrance amid the upward travel.
  4. The entryway administrator ought to not return the entryway to, and stop the entryway at, the total highest position when control is activated to halt the entryway amid the upward travel; the entryway can’t be moved to descend till the administrator switches the entryway a min of 2 inches.
  5. c) Inherent essential capture security for evenly sliding doors
  6. For an evenly sliding private carport entryway administrator framework, other than for the primary 1 foot of door travel from the complete closed position both with and without any outside entanglement security gadget utilitarian, the administrator of a closing private carport entryway ought to start inversion of the entryway inside 2 seconds of coming to the obstacle. After inversion of the entryway, the administrator ought to open the entryway a min of 2 inches from the edge of the obstruction.
  7. The entryway administrator ought to not open the entryway a min of 2 inches when the administrator faculties a moment obstacle whereas the closing course of travel.

iii.           The entryway administrator ought to not open the entryway a min of 2 inches when control is incited to halt the entryway amid development to the open position, but the entryway ought to not be moved to the open position till the administrator switches the entryway a min of 2 inches.

Secondary entrapment protection requirements

  1. For vertically moving entryway administrators, an auxiliary entanglement security gadget provided with, or as an adornment to, an administrator might comprise of:
  1. An outside photoelectric sensor when enacted ought to result in an administrator that’s closing an entryway to turn around heading of the entryway, returns the entryway to, and stops the door at the foremost open position, and the sensor ought to avoid an administrator from closing an open door.
  2. An outside edge sensor at the edge of the entryway, when activated ought to result in an administrator that’s closing an entryway to turn around heading of the entryway, too returns the entryway to, and stops the entryway at the completely open position. The sensor ought to avoid an administrator from closing an open door

iii.   The entryway administrator should not return the entryway to and halt the entryway at the completely open position when an inborn entanglement circuit faculties an obstacle amid the opening process.

  1. For flat sliding carport entryway administrators. An auxiliary capture security gadget provided with or as an extra too, an administrator ought to comprise of :
  2. An outside photoelectric sensor when actuated ought to result in an administrator that’s closing or opening an entryway to turn around heading of the entryway for a min of 2 inches or ought to result in an administrator that’s closing or opening an entryway to invert heading of the entryway for a min of 2 inches.